162
3.4 ASCII X Command Format
The ASCII X command is comprised of the following parts:
Group/Module/Window Assignment
The following is a list of rules to follow when entering the ASCII X command:
It is acceptable to enter commands in small or capital letters, and the five
columns are separated by a space.
Header = X + command character
Group/Module/Window Assignment (GGGMMMPPP) = is comprised of six
Arabic numerals. This is used in designating the device’s Group/Module/
Window Assignment.
Group = is comprised of the first three numbers (001 – 099), 000 is used to
pertain to all groups.
Module = is comprised of the middle three numbers (001, 002, . . .), 000 is
used to pertain to all modules.
Window Assignment = is comprised of the last three numbers (001,
002, . . .), 000 is used to pertain to all window assignments, 098 is used to
pertain to logo, 099 is used to pertain to clock.
Parameter 1 and Parameter 2 could pertain to the color assignment
(RRRGGGBBB) which is comprised of nine Arabic numerals, this is used in
designating the color; on / off switch where “1” signifies ON while “0”
signifies OFF; etc.; depending on the type of command.
The following is a list of available ASCII X commands:
XA
Format: XA GGGMMMPPP [NbyN(2 (2×2),3 (3×3),……)] [Nth(1,2,……)
position of window]
Function: to set the automatic arrangement of windows.