IMPORTANT: When cascading two or more modules (up to eight maximum) make sure
each module gets assigned a unique rotary ID or it will cause input conflicts.
2. To display video overlay from each module all units must be connected to
each other via male-to-male short DVI cascading cable. Take a DVI
cascading cable and connect one end to the OUTPUT-1 / -2 port on the Master
(first) module (N) and the other end to the CASCADE IN-1 / -2 port of the next
module in the chain (N+1).
3. The Rainier 3G is cascaded through RJ-45 (RS-485) which is used to loop
communication from one Rainier 3G to the next. The data stream carries
control and configuration information. Take the RS-485 cascading cable and
connect one end to the RS-485 OUT of the Master (first) Rainier 3G (N) and
the other end to RS-485 IN of the next Rainier 3G up (N+1). Refer to the
sample combination as follows: