174
XS
Format: XS GGGMMMPPP L[abel] / M[eter) 0 (fully transparent) – 8 (not
transparent)
Function: to set the label or meter’s transparency.
Examples: XS 001002000 L 8
sets all window labels of group 1, module 2 to no transparency.
XS 001000000 M 3
sets all modules’ meter in group 1 to transparency level 3.
NOTE: All windows will share the same label transparency setting. That is, upon changing
one window’s label transparency, all other window’s label transparency will also be
changed simultaneously.
XT
Format: XT GGGMMMPPP [0 is all tally / 1 – 3 = tally 1 – 3] 1 (on) / 0 (off)
Function: turn on or off the tally for a window or all the windows in a group.
Description: Designate the action of tally.
Examples: XT 001002003 2 1
activate tally 2 for window 3 in module 2 for group 1.
XT 001000000 0 0
close tally for all windows of all modules for group 1.
XU
Format: XU GGGMMMPPP [0 is all video input ports / 1 – 8 = video input
port number] "TEXT" (always center-aligned, supports ASCII
characters only – include the quotation marks).
NOTE: “000” is the fixed value for PPP in XU command.
Function: to set the umd (under monitor display) label’s text string.
Examples: XU 001002000 2 “UMD Label”
sets group 1, module 2, use video input port number 2, umd label’s
text string as "UMD Label."